Please use this identifier to cite or link to this item: http://repository.ukwk.ac.id/handle/123456789/1812
Title: Water Quality Analysis of Village and Monitoring Well around Rembang Steam Power Plant (EIA in Central Java, Indonesia)
Authors: Sunik
Dermawan, Very
Keywords: water quality sampling
village well and monitoring well
impact
hypothetical important impact
Issue Date: Aug-2017
Publisher: The Third International Conference on Civil Engineering Research (ICCER)
Abstract: Water quality sampling and monitoring of village well as a regular monitoring each quarter in a year for Rembang Steam Power Plant 2 x 315 MW was one part of EIA implementation study. This research aim to analysis the most impact occurrence that forecasted as a hypothetical important impact which is cause environmental change base on water quality sampling and monitoring from operational activity in first quarter (TW 1). Implementation method was used water sampling in 2(two) resident well and 6 (six) monitoring well in Trahan and Leran village, then the water sample was analyze in laboratory refer to the raw quality which has been set. The monitoring result on the residents wells quality was generally known that in the Trahan village residents wells (AB-1) found parameter that exceed quality standard i.e. total dissolved solids (TDS, come from river seepage and rainfall runoff), Chloride and Hardness,the high concentration some parameters, both exceed the quality standard as well as have a high critical level, generally was not caused by the operational activities of Rembang Steam Power Plant. Monitoring result from 6 (six) monitoring wells in location of Rembang Steam Power Plant was found parameters in several point that exceed the quality standard i.e. Turbidity in AB-3, organic chemical substance (KmnO4) in AB-3 and AB-7, TDS in AB-3 (monitoring wells 1), AB-4 (monitoring wells 2), AB5 (monitoring wells 3) and AB-7 (monitoring well 5), and AB-8 (monitoring wells 6). While the content of heavy metals that detected include arsenic, cadmium, lead, and selenium on AB-3.
URI: http://repository.ukwk.ac.id/handle/123456789/1812
Appears in Collections:International Proceeding

Files in This Item:
File Description SizeFormat 
8a_WaterQualityAnalysis_Sunik_IPTEKJournal.pdf1.3 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.